program() source options
The program
driver has the following options:
check-hostname()
Type: | boolean (yes or no ) |
Default: | Use the global check-hostname() option, which defaults to no . |
Checks that the hostname contains valid characters. Uses the value of the global option if not specified.
flags()
Type: | assume-utf8, empty-lines, expect-hostname, kernel, no-hostname, no-multi-line, no-parse, sanitize-utf8, store-legacy-msghdr, store-raw-message, syslog-protocol, validate-utf8 |
Default: | empty set |
Description: Specifies the log parsing options of the source.
-
assume-utf8: The
assume-utf8
flag assumes that the incoming messages are UTF-8 encoded, but does not verify the encoding. If you explicitly want to validate the UTF-8 encoding of the incoming message, use thevalidate-utf8
flag. -
empty-lines: Use the
empty-lines
flag to keep the empty lines of the messages. By default, AxoSyslog removes empty lines automatically. -
expect-hostname: If the
expect-hostname
flag is enabled, AxoSyslog will assume that the log message contains a hostname and parse the message accordingly. This is the default behavior for TCP sources. Note that pipe sources use theno-hostname
flag by default. -
guess-timezone: Attempt to guess the timezone of the message if this information is not available in the message. Works when the incoming message stream is close to real time, and the timezone information is missing from the timestamp.
-
kernel: The
kernel
flag makes the source default to theLOG_KERN | LOG_NOTICE
priority if not specified otherwise. -
no-header: The
no-header
flag triggers AxoSyslog to parse only thePRI
field of incoming messages, and put the rest of the message contents into$MSG
.Its functionality is similar to that of the
no-parse
flag, except theno-header
flag does not skip thePRI
field.Note Essentially, theno-header
flag signals AxoSyslog that thesyslog
header is not present (or does not adhere to the conventions / RFCs), so the entire message (except from thePRI
field) is put into$MSG
.Example: using the no-header flag with the syslog-parser() parser
The following example illustrates using the
no-header
flag with thesyslog-parser()
parser:parser p_syslog { syslog-parser( flags(no-header) ); };
-
no-hostname: Enable the
no-hostname
flag if the log message does not include the hostname of the sender host. That way AxoSyslog assumes that the first part of the message header is ${PROGRAM} instead of ${HOST}. For example:source s_dell { network( port(2000) flags(no-hostname) ); };
-
no-multi-line: The
no-multi-line
flag disables line-breaking in the messages: the entire message is converted to a single line. Note that this happens only if the underlying transport method actually supports multi-line messages. Currently thefile()
andpipe()
drivers support multi-line messages. -
no-parse: By default, AxoSyslog parses incoming messages as syslog messages. The
no-parse
flag completely disables syslog message parsing and processes the complete line as the message part of a syslog message. The AxoSyslog application will generate a new syslog header (timestamp, host, and so on) automatically and put the entire incoming message into the MESSAGE part of the syslog message (available using the${MESSAGE}
macro). This flag is useful for parsing messages not complying to the syslog format.If you are using the
flags(no-parse)
option, then syslog message parsing is completely disabled, and the entire incoming message is treated as the ${MESSAGE} part of a syslog message. In this case, AxoSyslog generates a new syslog header (timestamp, host, and so on) automatically. Note that even thoughflags(no-parse)
disables message parsing, some flags can still be used, for example, theno-multi-line
flag. -
dont-store-legacy-msghdr: By default, AxoSyslog stores the original incoming header of the log message. This is useful if the original format of a non-syslog-compliant message must be retained (AxoSyslog automatically corrects minor header errors, for example, adds a whitespace before
msg
in the following message:Jan 22 10:06:11 host program:msg
). If you do not want to store the original header of the message, enable thedont-store-legacy-msghdr
flag. -
sanitize-utf8: When using the
sanitize-utf8
flag, AxoSyslog converts non-UTF-8 input to an escaped form, which is valid UTF-8.Prior to version 4.6, this flag worked only when parsing RFC3164 messages. Starting with version 4.6, it works also for RFC5424 and raw messages.
-
store-raw-message: Save the original message as received from the client in the
${RAWMSG}
macro. You can forward this raw message in its original form to another AxoSyslog node using thesyslog-ng()
destination, or to a SIEM system, ensuring that the SIEM can process it. Available only in 3.16 and later. -
syslog-protocol: The
syslog-protocol
flag specifies that incoming messages are expected to be formatted according to the new IETF syslog protocol standard (RFC5424), but without the frame header. Note that this flag is not needed for thesyslog
driver, which handles only messages that have a frame header. -
validate-utf8: The
validate-utf8
flag enables encoding-verification for messages.Prior to version 4.6, this flag worked only when parsing RFC3164 messages. Starting with version 4.6, it works also for RFC5424 and raw messages.
For RFC5424-formatted messages, if the BOM character is missing, but the message is otherwise UTF-8 compliant, AxoSyslog automatically adds the BOM character to the message.
The byte order mark (BOM) is a Unicode character used to signal the byte-order of the message text.
hook-commands()
Description: This option makes it possible to execute external programs when the relevant driver is initialized or torn down. The hook-commands()
can be used with all source and destination drivers with the exception of the usertty()
and internal()
drivers.
Using hook-commands()
when AxoSyslog starts or stops
To execute an external program when AxoSyslog starts or stops, use the following options:
startup()
Type: | string |
---|---|
Default: | N/A |
Description: Defines the external program that is executed as AxoSyslog starts.
shutdown()
Type: | string |
---|---|
Default: | N/A |
Description: Defines the external program that is executed as AxoSyslog stops.
Using the hook-commands() when AxoSyslog reloads
To execute an external program when the AxoSyslog configuration is initiated or torn down, for example, on startup/shutdown or during a AxoSyslog reload, use the following options:
setup()
Type: | string |
---|---|
Default: | N/A |
Description: Defines an external program that is executed when the AxoSyslog configuration is initiated, for example, on startup or during a AxoSyslog reload.
teardown()
Type: | string |
---|---|
Default: | N/A |
Description: Defines an external program that is executed when the AxoSyslog configuration is stopped or torn down, for example, on shutdown or during a AxoSyslog reload.
Example: Using the hook-commands() with a network source
In the following example, the hook-commands()
is used with the network()
driver and it opens an iptables port automatically as AxoSyslog is started/stopped.
The assumption in this example is that the LOGCHAIN
chain is part of a larger ruleset that routes traffic to it. Whenever the AxoSyslog created rule is there, packets can flow, otherwise the port is closed.
source {
network(transport(udp)
hook-commands(
startup("iptables -I LOGCHAIN 1 -p udp --dport 514 -j ACCEPT")
shutdown("iptables -D LOGCHAIN 1")
)
);
};
keep-timestamp()
Type: | yes or no |
Default: | yes |
Description: Specifies whether AxoSyslog should accept the timestamp received from the sending application or client. If disabled, the time of reception will be used instead. This option can be specified globally, and per-source as well. The local setting of the source overrides the global option if available.
S_
macros, the keep-timestamp()
option must be enabled (this is the default behavior of AxoSyslog).
log-fetch-limit()
Type: | number |
Default: | 100 |
Description: The maximum number of messages fetched from a source during a single poll loop. The destination queues might fill up before flow-control could stop reading if log-fetch-limit()
is too high.
inherit-environment()
Type: | `yes |
Default: | yes |
Description: By default, when program()
starts an external application or script, it inherits the entire environment of the parent process (that is, AxoSyslog). Use inherit-environment(no)
to prevent this.
log-iw-size()
Type: | number |
Default: | 100 |
Description: The size of the initial window, this value is used during flow-control. Its value cannot be lower than 100, unless the dynamic-window-size()
option is enabled. For details on flow-control, see Managing incoming and outgoing messages with flow-control.
log-msg-size()
Type: | number (bytes) |
Default: | Use the global log-msg-size() option, which defaults to 65536 (64 KiB). |
Description: Maximum length of an incoming message in bytes. This length includes the entire message (the data structure and individual fields). The maximal value that can be set is 268435456 bytes (256 MiB).
For messages using the IETF-syslog message format (RFC5424), the maximal size of the value of an SDATA field is 64 KiB.
log-msg-size()
does not need to be set higher than 10 MiB.
For details on how encoding affects the size of the message, see Message size and encoding.
You can use human-readable units when setting configuration options. For details, seeNotes about the configuration syntax.
Uses the value of the global option if not specified.
log-prefix() (DEPRECATED)
Type: | string |
Default: |
Description: A string added to the beginning of every log message. It can be used to add an arbitrary string to any log source, though it is most commonly used for adding kernel:
to the kernel messages on Linux.
program-override
instead.
optional()
Type: | yes or no |
Default: |
Description: Instruct AxoSyslog to ignore the error if a specific source cannot be initialized. No other attempts to initialize the source will be made until the configuration is reloaded. This option currently applies to the pipe()
, unix-dgram
, and unix-stream
drivers.
pad-size()
Type: | number |
Default: | 0 |
Description: Specifies input padding. Some operating systems (such as HP-UX) pad all messages to block boundary. This option can be used to specify the block size. The AxoSyslog application will pad reads from the associated device to the number of bytes set in pad-size()
. Mostly used on HP-UX where /dev/log
is a named pipe and every write is padded to 2048 bytes. If pad-size()
was given and the incoming message does not fit into pad-size()
, AxoSyslog will not read anymore from this pipe and displays the following error message:
Padding was set, and couldn't read enough bytes
program()
Type: | filename with path |
Default: |
Description: The name of the application to start and read messages from.
program-override()
Type: | string |
Default: |
Description: Replaces the ${PROGRAM} part of the message with the parameter string. For example, to mark every message coming from the kernel, include the program-override("kernel")
option in the source containing /proc/kmsg
.
tags()
Type: | string |
Default: |
Description: Label the messages received from the source with custom tags. Tags must be unique, and enclosed between double quotes. When adding multiple tags, separate them with comma, for example, tags("dmz", "router")
. This option is available only in version 3.1 and later.
time-zone()
Type: | name of the timezone, or the timezone offset |
Default: |
Description: The default timezone for messages read from the source. Applies only if no timezone is specified within the message itself.
The timezone can be specified by using the name, for example, time-zone("Europe/Budapest")
), or as the timezone offset in +/-HH:MM format, for example, +01:00
). On Linux and UNIX platforms, the valid timezone names are listed under the /usr/share/zoneinfo
directory.