collectd: Send metrics to collectd

The collectd() destination uses the unixsock plugin of the collectd application to send log messages to the collectd system statistics collection daemon. You must install and configure collectd separately before using this destination.

Available in AxoSyslog version 3.20 and later.

Declaration:

   collectd();
   destination d_collectd {
      collectd(
        socket("<path-to-collectd-socket>"),
        host("${HOST}"),
        plugin("${PROGRAM}"),
        type("<type-of-the-collected-metric>"),
        values("<metric-sent-to-collectd>"),
      );
    };

Example: Using the collectd() driver

The following example uses the name of the application sending the log message as the plugin name, and the value of the ${SEQNUM} macro as the value of the metric sent to collectd.

   destination d_collectd {
      collectd(
        socket("/var/run/collectd-unixsock"),
        host("${HOST}"),
        plugin("${PROGRAM}"),
        type("gauge"),
        type_instance("seqnum"),
        values("${SEQNUM}"),
      );
    };

To use the collectd() driver, the scl.conf file must be included in your AxoSyslog configuration:

   @include "scl.conf"

The collectd() driver is actually a reusable configuration snippet configured to send log messages using the unix-stream() driver. For details on using or writing such configuration snippets, see Reusing configuration blocks. You can find the source of this configuration snippet on GitHub.

Last modified November 20, 2024: Broken link updates (5644de9)